TM 9-2320-269-20-2
EMERGENCY PUMP - TO - OUTRIGGER LINE HOSE ASSEMBLY
This task covers:
c.
Inspection/Replacement(page 2-1134)
b. Cleaning(page2-1133)
d.
Installation(page 2-11334)
INITIAL SETUP:
Tools
Materials/Parts - Continued
Pail, utility, 3-qt
Solvent, drycleaning (item 28, appendix C)
Wrench, open-end, 7/8-inch
Tape, teflon (item 32, appendix C)
Wrench, open-end, 1-inch
Wrench, open-end, 1 116-inch
Personnel Required
Materials/Parts
One
Detergent, non-sudsing (item 12,
appendix C)
Rags, wiping (item 24, appendix C)
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Avoid contact with hydraulic fluid. Hydraulic fluid, if splashed on skin or in eyes, can cause
irritation.
1.
Tank (1)
Shutoff valve (2)
Using 1 1/16-inch wrench, close.
2.
Two 900 swivel
Emergency pump-to-
a.
Position pail to catch hydraulic fluid.
adapters (3)
outrigger line hose
b.
Using 1-inch and 7/8-inch wrenches,
assembly (4)
unscrew and take off.
c.
Dispose of drained fluid.
2-1132