TM 9-2320-269-20-2
DERRICK OPERATOR'S CONTROL VALVE - TO - RETURN LINE FILTER HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
NOTE
Before installing hose assembly, wrap all clean, external threads with two turns of teflon
tape (page 2-142).
9.
900 swivel
Control valve-to-
a. Put in position using fish tape.
adapter (1)
return line filter
b. Screw on, and tighten using 7/8-inch
hose assembly (2)
and 1-inch wrenches.
10.
Derrick mast (3)
Access cover (4)
Put on.
11.
Access cover (4)
Two wing nuts (5)
Screw on, and tighten.
12.
900 swivel
Control valve-to-
Screw on, and tighten using 7/8-inch
adapter (6)
return line filter
and 1-inch wrenches
hose assembly (2)
TA229311
2-1128