TM 9-2320-269-20-2
DERRICK OPERATOR'S CONTROL VALVE - TO - RETURN LINE FILTER HOSE ASSEMBLY - CONTINUED
INSTALLATION - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1.
Fill with hydraulic fluid (LO 9-2320-269-12).
2.
Operate auxiliary equipment (TM 9-2320-269-10), and check for proper operation and leaks (page 2-
118).
TASK ENDS HERE
DERRICK OPERATOR'S FLOW CONTROL VALVE - TO - DERRICK OPERATOR'S CONTROL VALVE
HOSE ASSEMBLY
This task covers:
c.
Inspection/Replacement(page 2-1130)
b. Cleaning(page2-1130)
d.
Installation(page 2-11331)
INITIAL SETUP:
Tools
Materials/Parts
Pail, utility, 3-qt
Detergent, non-sudsing (item 12,
Wrench, open-end, 7/8-inch
appendix C)
Wrench, open-end, 1-inch
Rags, wiping (item 24, appendix C)
Solvent, drycleaning (item 28, appendix C)
Tape, teflon (item 32, appendix C)
Personnel Required
One
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Avoid contact with hydraulic fluid. Hydraulic fluid, if splashed on skin or in eyes, can cause
irritation.
2-1129