TM 9-2320-269-20-2
EMERGENCY PUMP - TO - OUTRIGGER LINE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
NOTE
For more information on how to clean parts, go to General Maintenance Instructions
(page 2-142).
3.
All metal parts
a. Clean in drycleaning solvent.
b.
Wipe dry with clean, dry rags.
4.
Hose assembly (1)
a. Clean in clean, soapy water.
b. Rinse in clean water.
c. Wipe connectors clean with clean rags
dampened in drycleaning solvent.
d. Wipe dry with clean, dry rags.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-142).
Replace damaged or defective parts as necessary.
5.
Emergency pump-to-
a. Look for cracks, breaks, tears, and
outrigger line
hose assembly (1)
b. Look for loose connectors.
c.
Look for damaged threads.
6.
All threaded parts
Look for stripped and gouged threads.
INSTALLATION
NOTE
Before installing hose assembly, wrap all clean, external threads with two turns of teflon
tape (page 2-142).
7.
Two 900 swivel
Emergency pump-to-
Screw on, and tighten using 1-inch and
adapters (2)
outrigger line
718-inch wrenches.
hose assembly (1)
2-1134