TM 9-2320-269-20-2
FRONT WINCH CM2 VALVE - TO - RETURN LINE FILTER HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-142).
Replace damaged or defective parts as necessary.
7.
CM2 valve-to-return
Look for cracks, breaks, tears, or
line filter hose (1)
8.
All threaded parts
Look for stripped and gouged threads.
INSTALLATION
9.
Dixon insert (2)
CM2 valve-to-return
Push on.
line filter hose (1)
10
CM2 valve-to-return
Clamp (3), two
a. Place in position.
line filter hose (1)
screws (4), and two
b. Screw on, and tighten using 11/16-
nuts (5)
inch socket and handle.
11
Dixon insert (6)
CM2 valve-to-return
a. Put in position.
line filter hose (2)
b. Push on.
12.
CM2 valve-to-return
Clamp (7), two
a. Place in position.
line filter hose (1)
screws (8), and two
b. Screw on, and tighten using 11/16-
nuts (9)
inch socket and handle.
2-1138