TM 9-2320-269-20-2
CHECK VALVE - TO - FLOW CONTROL VALVE TEE HOSE ASSEMBLY
This task covers:
INITIAL SETUP
Tools
Material/Parts - Continued
Pail, utility, 3-qt
Solvent, drycleaning (item 28,
Wrench, open-end, 7/8-inch
appendix C)
Wrench, open-end, 1-inch
Tape, teflon (item 32, appendix C)
Materials/Parts
Personnel Required
Detergent, non-sudsing (item 12,
One
appendix C)
Rags, wiping (item 24, appendix C)
Equipment Condition
Operator's platform down
(TM 9-2320-269-10).
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Avoid contact with hydraulic fluid. Hydraulic fluid if splashed on skin or in eyes can cause
irritation.
1.
Hose assembly (2)
a. Position pail to catch hydraulic fluid.
valve tee (1)
b. Using 7/8-inch and 1-inch wrenches,
unscrew, take off, and push aside.
c.
Dispose of drained fluid.
2-1108