TM 9-2320-269-20-2
CHECK VALVE - TO - FLOW CONTROL VALVE TEE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING- CONTINUED
3.
All metal parts
a.
Clean in drycleaning solvent.
b.
Wipe dry with clean, dry rags.
4.
Hose
a.
Clean in clean soapy water.
assembly (1)
b.
Rinse in clean water.
c.
Wipe connectors clean with clean
rags dampened in drycleaning solvent.
d. Wipe dry with clean, dry rags.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-142).
Replace damaged or defective parts as necessary.
5.
Hose
a. Look for cracks, breaks, tears, and
assembly (1)
b. Look for loose connectors.
c. Look for damaged threads.
6.
All threaded parts
Look for stripped and gouged threads.
INSTALLATION
NOTE
Before installing hose assemblies, wrap all clean, external threads with two turns of teflon
tape (page 2-142).
2-1110