TM 9-2320-269-20-1
POWER DIVIDER LOCKOUT VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Drain air from system before removing lines or fittings to avoid personnel Injury from compressed air.
NOTE
See General Maintenance Instructions on tagging lines before removal to aid in installation (page 2-142).
1. Plate (1)
Screw (2), nut (3),
a. Using screwdriver and 11/32-inch
and ground wire (4)
wrench, unscrew and take out.
b. Tape ground wire to any wire under
dash panel.
c. Get rid of screw (2).
2. Dash panel (5)
Two screws (6), two
a. Using screwdriver, unscrew, take out,
plates (1) and (7),
and take off plate.
and valve (8)
b. Using twisting motion, take out
valve from under dash panel.
3. Valve (8)
Two linenuts (9)
a. Using 7/16-inch and 9/16-inch
and lines (10)
wrenches, unscrew and take off.
b. Tag lines.
4.
Coupling (11)
Using 7/16-inch wrench, unscrew and
and elbow (12)
take out.
5.
Plug (13)
Using socket-head screw key, take out.
2-503