TM 9-2320-269-20-2
TANK - TO - PUMP HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-142.)
Replace damaged or defective parts as necessary.
6.
Tank-to-pump
Look for cracks, breaks, tears, and
hose (1)
7.
All metal parts
Look for stripped or gouged threads.
INSTALLATION
8.
Dixon insert (2)
Tank-to-pump
Push on.
hydraulic pump
hose (1)
inlet (3)
9.
Tank-to-pump
Two clamps (4),
a. Place in position.
hose (1)
four screws (5),
b. Screw on, and tighten using 11/16-inch
and nuts (6)
socket and handle.
10
Hydraulic
shutoff valve(8)
Using 1 1/16-inch wrench, turn on.
TA229350