SOLENOID VALVE - TO - FLOW CONTROL VALVE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
NOTE
Before installing hose assembly, wrap all clean, external threads with two turns of teflon tape (page 2-142).
6.
Swivel adapter
a. Put in position.
(2) to swivel
flow control valve
b. Screw on, and tighten using 718-inch
tee adapter (1)
hose assembly (3)
and 1-inch wrenches.
NOTE
FOLLOW-ON MAINTENANCE:
1. Raise operator's platform (TM 9-2320-269-10).
2. Operate auxiliary equipment (TM 9-2320-269-10), and
check for proper operation and leaks.
TASK ENDS HERE
TA229348
2-1201