TM 9-2320-269-20-2
SOLENOID VALVE - TO - FLOW CONTROL VALVE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL-CONTINUED
1.
Swivel tee
a. Position pail to catch hydraulic
adapter (1) to
flow control valve
fluid.
swivel adapter (2)
hose assembly (3)
b. Using 7/8-inch and 1-inch wrenches,
c. Take out of truck.
d. Get rid of fluid.
CLEANING
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when using
solvent. Failure to observe these precautions could cause serious injury or death.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-142).
2.
All metal parts
a. Clean in drycleaning solvent.
b. Wipe dry with clean, dry rags.
3.
Hose assembly (3)
a. Clean in clean, soapy water.
b. Rinse in clean water.
c. Wipe connectors clean with clean
rags dampened with drycleaning
solvent.
d. Wipe dry with clean, dry rags.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-142).
Replace damaged or defective parts as necessary.
4.
Hose assembly (3)
a. Look for cracks,breaks, tears, and
b. Look for loose connectors.
c. Look for damaged threads.
5.
All threaded parts
Look for stripped and gouged threads.
2-1200