TM 9-2320-269-20-2
HEATER ASSEMBLY, HEAT CONTROL, AND VENT CONTROL - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY - CONTINUED
59.
Heater assembly (1)
HEAT cable (2)
a. Route a piece of wire through hole
(3) under blower housing.
b. Work through blower holes up
through hole (4) in top of heater.
c. Tie wire onto door end of cable (2).
d. Using wire, pull cable (2) into
place.
60.
Heater door
Spring (7)
Put in place so door (hidden) is held
arm (5) and
shut.
spring stop (6)
61.
Heater
HEAT cable (2)
Put loop end onto arm (5).
door arm (5)
62.
Clip
HEAT cable (2)
Put in place, and hold.
support (8)
63.
HEAT cable (2)
Clip (9) and
Screw in, and tighten using 1 1/2-inch
to clip
screw (10)
cross-tip screwdriver.
support (8)
64.
HEAT cable (2)
New push nut (11)
Using long-nose pliers, push on.
to heater
door arm (5)
65.
Heater assembly (1)
Grommets (12)
Push in using flat-tip screwdriver.
and (13)
NOTE
2-1280