TM 9-2320-269-20-2
HEATER ASSEMBLY, HEAT CONTROL, AND VENT CONTROL - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY - CONTINUED
66.
Heater assembly (1)
Blower
a. Turn flat cut-out on blower mounting
assembly (2)
plate (3) so it is on the right side.
b. Put blower assembly (2) into place.
c. Turn mounting plate (3) so flat cut-
out is at two-o'clock position.
d. Let blower assembly (2) down so it
rests on floor of heater (1).
67.
Orange wire (4)
Push up through hole (5) in top of
heater (1), and pull through
until all of wire (4) is outside heater
except enough to get from hole (5)
to blower (2).
68.
Red wire (6)
Push up through hole (5) in top of heater
(1), and pull through until all of
wire (6) is outside heater (1) except
enough to get from hole (5) to
blower (2).
69.
Grommet (7)
Push into hole (5) around wires (4)
and (6) using flat-tip screwdriver.
70.
Heater assembly (1)
Blower assembly (2)
Pick up, and aline holes in heater (1)
with holes in blower mounting plate (3).
71.
Mounting plate (3)
Ground wire (8)
Put in place, and hold.
to heater
assembly (1)
72.
Ground wire (8) to
One screw of
Screw in, and tighten using 1 1/2-inch
heater assembly (1)
six (9)
cross-tip screwdriver.
and mounting
plate (3)
2-1282