TM 9-2320-269-20-2
PUMP FLOW CONTROL VALVE - TO - QUICK DISCONNECT HOSE ASSEMBLY - CONTINUED
INSTALLATION - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1. Fill with hydraulic fluid (LO 9-2320-269-12).
2. Operate auxiliary equipment (TM 9-2320-269-10),
and check for proper operation and leaks.
TASK ENDS HERE
RETURN LINE - TO - TANK HOSE
This task covers:
a. Removal(page2-1178)
INITIAL SETUP
Tools
Materials/Parts
Fish tape, 50-ft reel
Detergent, non-sudsing (item 12, appendix C)
Rags, wiping (item 24, appendix C)
Pail, utility, 6-qt
Solvent, drycleaning (item 28, appendix C)
Screwdriver, 3/8-inch, flat-tip
Socket, -inch drive,
Personnel Required
11/16-inch
One
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Avoid contact with hydraulic fluid. Hydraulic fluid, if splashed on skin or in eyes, can cause irritation.
1.
Return line-
Clamp (2), two
a. Position pail to catch hydraulic fluid.
to-tank
screws (3), and
b. Using 11/16-inch socket and handle,
hose (1)
nuts (4)
unscrew and take off.
c. Dispose of drained fluid.
2-1178