TM 9-2320-269-20-2
PUMP FLOW CONTROL VALVE - TO - QUICK - DISCONNECT HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
NOTE
Before installing hose assemblies, wrap all clean, external threads with two turns of teflon tape (page 2-
142).
13.
Quick-disconnect
Screw on using 1 114-inch wrench
hose assembly (2)
and pipe wrench.
14.
Straight swivel
Quick-disconnect
Screw on, and tighten using 7/8-inch
adapter (3)
hose assembly (2)
and 1-inch wrenches.
15.
Quick-disconnect
Quick-disconnect
Screw on, and tighten using 7/8-inch
hose assembly (2)
body (4)
and 1 -inch wrenches.
16.
Frame channel (5)
Quick-disconnect
Put in position.
hose assembly (6)
17.
Quick-disconnect
Two clamps (7),
a
Place in position.
hose assembly (6)
screws (8), and
b. Screw on, and tighten using 7/16-inch
nuts (9)
socket, extension, handle, and 7/16-
inch wrench.
18.
Quick-disconnect
Two clamps (10),
a. Place in position.
hose assembly (6)
screws (11), and
b. Screw on, and tighten using 7/16-inch
nuts (12)
socket, extension, handle, and 7/16-
inch wrench.
19.
Quick-disconnect
Quick-disconnect
Connect.
hose (6)
body (13)
20.
Hydraulic
Shutoff valve (15)
Using 1 1/16-inch wrench, turn on.
tank (14)
2-1176