TM 9-2320-269-20-2
RETURN LINE - TO - TANK HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flames nearby when using
solvent. Failure to observe these precautions could cause serious injury or death.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-142).
5.
All metal parts
a. Clean in drycleaning solvent.
b. Wipe dry with clean, dry rags.
6.
Return line-to-
a. Clean in clean, soapy water.
tank hose (1)
b. Rinse in clean water.
c. Wipe connectors clean with clean rags
dampened with drycleaning solvent.
d. Wipe dry with clean, dry rags.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-142).
Replace damaged or defective parts as necessary.
7.
Return line-to-
Look for cracks, breaks, tears,
tank hose (1)
8.
All threaded parts
Look for stripped and gouged threads.
INSTALLATION
9.
Dixon insert (2)
Return line-to-
Push on.
tank hose (1)
10.
Return line-
Clamp (3), two
a. Place in position.
to-tank
screws (4), and
b. Screw on, and tighten using handle
hose (1)
nuts (5)
and 11/16-inch socket.