TM 9-2320-269-20-2
RETURN LINE - TO - TANK HOSE - CONTINUED
INSTALLATION - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1. Fill with hydraulic fluid (LO 9-2320-269-12).
2. Operate auxiliary equipment (TM 9-2320-269-10),
and check for proper operation and leaks.
TASK ENDS HERE
SINGLE SELECTOR VALVE - TO - DERRICK OPERATOR'S CONTROL VALVE HOSE ASSEMBLY
This task covers:
a. Removal
c. Inspection
e.
Pre-Load Check of Bearing
b. Disassembly
d. Reassembly
f.
Installation
INITIAL SETUP:
Tools
Materials/Parts
Fish tape, 50-ft reel
Detergent, non-sudsing (item 12, appendix C)
Pail, utility, 6-qt
Rags, wiping (item 24, appendix C)
Wrench, open-end, 9/16-inch
Solvent, drycleaning (item 28, appendix C)
Wrench, open-end, 11/16-inch
Tags, marking (item 29, appendix C)
Wrench, open-end, 7/8-inch,
Tape, teflon (item 32, appendix C)
Wrench, open-end, 1-inch
Personnel Required
One
Equipment Condition
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Avoid contact with hydraulic fluid. Hydraulic fluid, if splashed on skin or in eyes, can cause irritation.
2-1182