TM 9-2320-269-20-2
SINGLE SELECTOR VALVE - TO - DERRICK OPERATOR'S CONTROL VALVE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEM ENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-142).
Replace damaged or defective parts as necessary.
10.
Selector valve-to-
a. Look for cracks, breaks, tears,
control valve hose
assembly (1)
b. Look for loose connectors.
c. Look for damaged threads.
11.
All threaded parts
Look for stripped and gouged threads.
INSTALLATION
NOTE
Before installing hose assemblies, wrap all clean, external threads with two turns of teflon tape (page 2-
142).
12.
90 swivel
Selector valve-to-
a. Put in position using fish tape.
adapter (2)
control valve hose
b. Screw on, and tighten using 7/8-inch
assembly (1)
and 1-inch wrenches.
TA229340
2-1186