TM 9-2320-269-20-2
PUMP - TO - CONSOLE CM2 VALVE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
1.
Hydraulic tank (1)
Shutoff valve (2)
Using 1 1/16-inch wrench, turn off.
2.
Swivel adapter (3)
Pump-to-console
a. Position pail to catch hydraulic fluid.
CM2 valve hose
b. Using two 1 114-inch wrenches,
assembly (4)
unscrew and take off.
c. Dispose of drained fluid.
3.
Two swivel
Two hose
a. Tag adapters (5) and hoses (6).
adapters (5)
assemblies (6)
b. Using 7/8-inch and 1-inch wrenches,
4.
Two adapters (7)
Two swivel
Using 1-inch and 1 -inch wrenches,
adapters (5)
unscrew and take off.
5.
Adapter(8)
90% swivel
Using 1 -inch and 1 -inch
adapter (9)
wrenches, unscrew and take off.
6.
90% swivel
Pump-to-console
Using two 1 -inch wrenches,
adapter (9)
CM2 valve hose
unscrew and take off.
assembly (4)
CLEANING
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when using
solvent. Failure to observe these precautions could cause serious injury or death.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-142)..
7.
All metal parts
a. Clean in drycleaning solvent.
b. Wipe dry with clean, dry rags
8.
Hose assembly (4)
a. Clean in clean, soapy water.
b. Rinse in clean water.
c. Wipe connectors clean with clean rags
dampened with drycleaning solvent.
d. Wipe dry with clean, dry rags.
2-1160