TM 9-2320-269-20-2
PUMP - TO - CONSOLE CM2 VALVE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT- CONTINUED
9.
Hose assembly (1)
a. Look for cracks, breaks, tears,
b. Look for loose connectors.
c. Look for damaged threads.
10.
All threaded parts
Look for stripped and gouged threads.
INSTALLATION
NOTE
Before installing hose assemblies, wrap all clean, external threads with two turns of teflon tape (page 2-
142).
11.
Console CM2
Pump-to-console
Put in position using fish tape.
valve (2)
CM2 valve hose
assembly (1)
12.
Pump-to-console CM2
900 swivel
Screw on, and tighten using two
valve hose assem-
adapter (3)
1 -inch wrenches.
bly (1)
13.
Adapter (4)
900 swivel
Screw on, and tighten using 1 114-inch
adapter (3)
and 1 -inch wrenches.
14.
Two adapters (5)
Two swivel
Screw in, and tighten using 1-inch and
adapters (6)
and 1 -inch wrenches.
15.
Two swivel
Two hose
Screw on, and tighten using 7/8-inch
adapters (6)
assemblies (7)
and 1-inch wrenches.
16.
Swivel
Pump-to-console
Screw on, and tighten using 7/8-inch
adapter (8)
CM2 valve hose
and 1 -inch wrenches.
assembly (1)
17.
Hydraulic tank (9)
Shutoff valve (10)
Using 1 1/16-inch wrench, turn on.
2-1162