TM 9-2320-269-20-2
CONSOLE CM2 VALVE - TO - RETURN LINE FILTER HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
12. Dixon insert (1)
Hose (2)
Put on.
13. Hose (2)
Clamp (3), two
a Put in position.
screws (4). and two
b. Screw on, and tighten using 9/16-
nuts (5)
inch socket, handle, and 9/16-inch
wrench.
14.
Adapter (6)
a. Using fish tape, route hose (2) into
and dixon insert (7)
position.
b. Put on.
15. Console CM2
Adapter (6) and
Screw in, and tighten using 1 7/8-inch
valve (8)
new preformed
wrench.
packing (9)
16
Hose (1)
Clamp (10), two
a. Put in position.
screws (11), an d
b. Screw on, and tighten using 9/16-inch
two nuts (12)
socket, handle, and 9/16-inch wrench.
2-1116