TM 9-2320-269-20-2
CONSOLE CM11 VALVE - TO - RETURN LINE FILTER HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
NOTE
Before installing hose assembly, wrap all clean, external threads with two turns of teflon
tape (page 2-142).
7.
Straight swivel
CM11 valve-to-
a. Put in position using fish tape.
adapter (1)
return line filter
b. Screw on, and tighten using 718-inch
hose assembly (2)
inch and 1-inch wrenches.
8.
Tee (3)
CM11 valve-to-
Screw on, and tighten using 7/8-inch
return line filter
and 1-inch wrenches.
hose assembly (2)
NOTE
FOLLOW-ON MAINTENANCE:
1.
2.
Fill with hydraulic fluid (LO 9-2320-269-12).
3.
Operate auxiliary equipment (TM 9-2320-269-10), and check for proper operation and leaks.
TA229307
TASK ENDS HERE
2-1120