TM 9-2320-269-20-2
AUGER DRAIN LINE - TO - RETURN LINE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
2.
Access cover (1)
Two wingnuts (2)
Unscrew, and take off.
3.
Derrick mast (3)
Access cover (1)
Take off.
4.
Straight swivel
Auger drain line-
a.
Using 718-inch and i-inch wrenches,
adapter (4)
to-return line
unscrew and take off.
hose assembly (5)
b. Pull out of truck.
CLEANING
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame
near by when using solvent. Failure to observe these precautions could cause serious
injury or death.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions
(page 2-142).
5.
All metal parts
a.
Clean in drycleaning solvent.
b.
Wipe dry with clean, dry rags.
6.
Hose assembly (5)
a.
Clean in clean, soapy water.
b.
Rinse in clean water.
c.
Wipe connectors clean with clean rags
dampened in drycleaning solvent.
d. Wipe dry with clean, dry rags.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-142).
Replace damaged or defective parts as necessary.
2-1098