TM 9-2320-269-20-1
AIR PRESSURE INDICATOR SWITCH
This task covers:
INITIAL SETUP:
Tools
Personnel Required
Screwdriver, flat-tip, 5/16-inch
One
Wrench, open-end, 3/4-inch
Equipment Condition
Materials/Parts
Battery ground cable disconnected
Tape, teflon
(item 32, appendix C)
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Drain air from system before removing lines or fittings to avoid personnel injury due to compressed air.
1. Switch tab (1)
Screw (2) and lead
Using flat-tip screwdriver, unscrew
wire (3)
and take out.
2. Fitting (4)
Switch (5)
Using 3/4-inch wrench, unscrew and
take out.
2-513