TM 9-2320-269-20-2
BLOWER ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
23.
Heater (1)
Blower
Put in, and let assembly (2) sit on
assembly (2)
floor of heater (1).
24.
Orange wire (3)
Thread through hole in heater (1), and
pull through as far as possible without
lifting blower (2).
25.
Red wire (4)
Thread through hole in heater (1), and
pull through as far as possible without
lifting blower (2).
26.
Grommet (5)
Using flat-tip screwdriver, work into
hole in heater around wires (3) and (4).
27.
Motor mounting
Five of six sheet
a. Lift blower assembly (2) into place.
plate (6) to
metal screws (7)
b. Screw in, and tighten using cross-tip
heater (1)screwdriver.
28.
Motor mounting
Ground wire (8)
Put in place, and hold.
plate (6)
29.
Ground wire (8)
One of six sheet
Screw in, and tighten using cross-tip
and motor mounting
metal screws (7)
screwdriver.
plate (6) to
heater (1)
30.
Heater (1)
Motor cover (9)
Put in place, and hold.
31.
Motor cover (9)
Three sheet metal
Screw in, and tighten using cross-tip
to heater (1)
screws (10)
screwdriver.
2-1266