TM 9-2320-269-20-2
PUMP FLOW CONTROL VALVE - TO - RETURN LINE HOSE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
4.
Hose assembly (1)
a. Clean in clean, soapy water.
b. Rinse in clean water.
c. Wipe connectors clean with clean
rags dampened in drycleaning solvent.
INSPECTIONIREPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-142.)
Replace damaged or defective parts as necessary.
5.
Hose assembly (1)
a. Look for cracks, breaks, te ars, and
b. Look for loose connectors.
c.
Look for damaged threads.
6.
All threaded parts
Look for stripped and gouged threads.
INSTALLATION
NOTE
Before installing hose assembly, wrap all clean, external threads with two turns of teflon tape (page 2-
142).
7.
Straight swivel
Pump flow control
Screw on, and tighten using 7/8-inch
adapter (2) and
valve-to-return
and 1-inch wrenches.
45% swivel
line hose
adapter (3)
assembly (1)
2-1170