TM 9-2320-269-20-2
RIGHT SIDE OUTRIGGER CONTROL VALVE - TO - LEFT SIDE OUTRIGGER CONTROL VALVE HOSE ASSEMBLY -
CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT- CONTINUED
6.
All threaded parts
Look for stripped and gouged threads.
INSTALLATION
NOTE
Before installing hose assembly, wrap all clean, external threads with two turns of teflon
tape (page 2-142).
7.
Two 900 swivel
Outrigger control
a. Pass into console (3), and pull
adapters (1)
valve-to-outrigger
through using fish tape.
control valve hose
b. Put in position.
assembly (2)
c. Screw on , and tighten using 7/8-inch
and 1-inch wrenches.
NOTE
FOLLOW-ON MAINTENANCE:
1.
Fill with hydraulic fluid (LO 9-2320-269-12).
2.
Turn on hydraulic tank shutoff valve (TM 9-2320-269-10).
3.
TASK ENDS HERE
TA229319
2-1145