TM 9-2320-269-20-1
DOUBLE CHECK VALVES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
STANDARD DOUBLE CHECK VALVE REMOVAL
WARNING
Drain air from system before removing lines and fittings to avoid personnel injury from compressed air.
NOTE
1. Coupling (1)
Line (2)
Using 5/8-inch and 11/16-inch wrenches,
unscrew and take off.
2. Two elbows (3)
Two lines (4)
Using 5/8-inch and 11/16-inch wrenches,
unscrew and take off.
3.
Bracket (5)
Nut (6), screw (7),
Using 1/2-inch socket, extension, handle,
and valve (8)
and 1/2-inch wrench, unscrew and
take off.
NOTE
Tag locations of fittings before removal to aid in installation (page 2-142).
4. Valve (8)
Coupling (1)
Using 11/16-inch wrench, unscrew and
and two elbows (3)
take off.
TA228895
2-522