TM 9-2320-269-20-1
INSTRUMENT PANEL WARNING LIGHTS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
5.
Lens fitting (3)
Take out.
INSTALLATION
NOTE
To only change bulb, go to step 9.
6.
Instrument panel (1)
Lens fitting (3)
Put in.
7.
Lens fitting (3)
New lockwasher (7)
Screw on, and tighten using long
and retaining
round-nose pliers.
nut (6)
NOTE
Check wire markings from removal to insure proper hookup.
8.
Socket lead wire (8)
Terminal (9)
a. Using wire strippers, strip 1/2-inch
and harness lead
(12.69 mm) of insulation from wires
wire (5)
(5) and (8) and fold back onto
casing (10).
b. Put wires (5) and (8) into terminal (9),
and crimp together using crimping
tool.
TA228786