TM 9-2320-269-20-1
THERMOSTATS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
30.
Water outlet(13)
Hose (14) with
Push on while twisting and turning.
clamp (15)
31.
Radiator (16)
Hose (14) with
Push on while twisting and turning.
clamp (17)
32.
Hose (14)
Two clamps
Locate 1/4-inch from end.
(15) and (17)
33.
Clamp (15)
Screw (18)
Screw in, and tighten using screwdriver.
34.
Clamp (17)
Screw (19)
Screw in, and tighten using screwdriver.
NOTE
FOLLOW-ON MAINTENANCE:
TASK ENDS HERE
TA228725
2-243