TM 9-2320-269-20-2
FANITEMP SWITCH AND CABLE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
23.
Valve (1)
FAN/TEMP
Put in place with loop on end of cable
cable (2)
on pin of valve lever (3).
24.
Cable (2) to
Clip (4)
Put over cable (2) and onto valve (1)
valve (1)
so cable (2) is in groove.
25.
Clip (4) to
Screw (5)
Screw in, and tighten using 1/4-inch
valve (1)
socket and handle.
26.
Cable (2) to
Push nut (6)
Using pliers, push onto pin of valve
valve (1)
lever (3).
27.
Firewall (7)
Grommet (8)
Push into place using screwdriver.
and cable (2)
NOTE
FOLLOW-ON MAINTENANCE:
1. Close right side of hood (page 2-7).
2. Connect battery ground cable (page 2-414).
TASK ENDS HERE
TA229665