TM 9-2320-269-20-1
AUTOMATIC RESERVOIR DRAIN VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
1.
Reservoir (1)
Drain valve (2)
Using 11/16-inch wrench, unscrew and take off.
CLEANING
WARNING
Drycleaning solvent vapors are poisonous and highly flammable. Always work in well-ventilated area. To prevent
injury to
personnel, do not smoke or allow solvent near open flames.
2.
Reservoir (1)
a. Flush with drycleaning solvent to
remove dirt and moisture.
b. Air dry.
INSTALLATION
NOTE
Replace valve in proper position to insure proper hookup.
3.
Reservoir (1)
Drain valve (2)
a. Wipe threads clean, and wrap
b. Screw in, and tighten using 11/16 inch wrench.
TA228947
2-588