TM 9-2320-269-20-1
INVERSION VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
9. Crossmember (1)
Valve (2)
Place in position.
10. Valve (2)
Two screws (3)
Screw in, and tighten using 112-inch deep
and nuts (4)
well socket, extension, handle, and
1/2-inch wrench.
NOTE
Check tags on lines from removal to insure proper hookup.
11. Elbow (5)
Line (6)
Screw in, and tighten using 5/8-inch
and 9/16-inch wrenches.
12. Coupling (7)
Line (8)
Screw in, and tighten using two
9/16-inch wrenches.
13. Elbow (9) and
Two lines (11)
Screw in, and tighten using 5/8-inch
coupling (10)
and 9/16-inch wrenches.
TA228914
2-538