TM 9-2320-269-20-1
FAN ASSEMBLY AND MODULATED FAN DRIVE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
8. Modulated fan drive
Fan assembly (2)
Put in position.
assembly (1)
9.
Four new lock-
Screw in, and tighten using 1/2-inch
washers (3) and
open-end wrench.
screws (4)
10. Water pump pulley
Modulated fan
a. Line up, and start threads.
hub (5)
derive sleeve (6)
b. Place screwdriver blade or pry bar
through opening in water pump pulley
hub, and rest on water pump body hub
to serve as stop against one pulley
hub spoke.
c. Using adjustable wrench, turn drive
sleeve (6) until snug.
d. Tighten to 40 ft-lb (54 N m) of torque
using torque wrench and 2 1/8-inch
crowfoot attachment.
TA228749
2-272