TM 9-2320-269-20-1
Section VIII. FUEL SYSTEM
Page
Page
Accelerator Control Cable ........................................... 2-185
Fuel Pump ................................................................2-167
Accelerator Pedal ........................................................ 2-180
Fuel Return Lines .....................................................2-173
Accelerator Pedal Rod................................................. 2-182
Fuel Shutoff Cable....................................................2-193
Air Cleaner................................................................... 2-152
Fuel Supply Lines .....................................................2-170
Fuel Filters................................................................... 2-178
Fuel Tank .................................................................2-160
Fuel Filter Supply Line................................................. 2-176
Throttle Cable ...........................................................2-190
AIR CLEANER
This task covers:
INITIAL SETUP
Tools
Materials/Parts
Hammer, rubber
Element, air filter
Gasket, air cleaner body
Screwdriver, flat-tip, 3/16-inch
Gasket, engine adapter (two required)
Socket, deep well, 1/2-inch drive,
1/2-inch
Personnel Required
Wrench, open-end, 1-inch
(two required)
One
Equipment Condition
WARNING
After Nuclear, Biological, or Chemical (NBC) exposure of this vehicle, all air filters shall be handled with
extreme caution. Unprotected personnel may experience injury or death if residual toxic agents or
radioactive material are present. If vehicle is exposed to chemical or biological agents, servicing personnel
shall wear protective mask, hood, protective overgarments, and chemical protective gloves and boots. All
contaminated air filters shall be placed into double-lined plastic bags and moved to a segregation area
away from the worksite swiftly. The same procedure applies for radioactive dust contamination, however,
the Company NBC team should measure the radiation prior to filter removal to determine the extent of
safety procedures required per the NBC Annex to the unit Standard Operating Procedures (SOP). The
segregation area in which the contaminated air filters are temporarily stored shall be marked with
appropriate NBC placards. Final disposal of contaminated air filters shall be in accordance with local SOP.
2-152