TM 9-2320-269-20-2
AUGER HYDRAULIC DRIVE LINES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
36.
Console (1) and
Two valve-to-
With help from assistant, and using fish
derrick mast (2)
connector hose
tape, pass hoses (3) and (4) from con-
assemblies (3)
sole (1) up through mast until positi-
and (4)
oned at feed tube-to-connector hose
assemblies (5) and (6) in mast access
opening.
37.
Feed tube-to
Swivel
Screw on, and tighten using two
connector hose
adapter (7)
1 1/4-inch wrenches.
assembly (5)
38.
Feed tube-to-
Swivel
Screw on, and tighten using two
connector hose
adapter (8)
1 1/4-inch wrenches.
assembly (6)
39.
Swivel
Valve-to-
a. Check tag for proper location, and
adapter (7)
connector hose
take off.
assembly (3)
b. Screw on, and tighten using two
1 114-inch wrenches.
40.
Swivel
Valve-to-
a. Check tag for proper location, and
adapter (8)
connector hose
take off.
assembly (4)
b. Screw on, and tighten using two
1 1/4-inch wrenches.
2-938