TM 9-2320-269-20-1
STARTING MOTOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
NOTE
Before installing solenoid lead wires, check tags to insure proper placement.
Clean all terminals and cable ends with wire brush before replacement to insure proper
connections.
21. Solenoid (9)
Magnetic switch lead
a. Takeoff tags.
wire (10), converter
b. Position onto solenoid terminal (13).
cable (11), and
positive battery
cable (12)
22.
Nut (14)
Screw on, and tighten using 3/4-inch
socket, extension, handle, and 314-inch
wrench
TA228764
2-295