TM 9-2320-269-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONTINUED
24-VOLT CONVERTER NOT WORKING - CONTINUED
Step 8. Test converter (2) for 24 volts - Continued
d. Turn key switch and converter switch to the OFF position.
e. If meter reads less than 24 volts at any terminal (6), (7), and (8), replace converter (2) (page 2-425).
f. Install seat back (4) using 9/16-inch wrench, and notify Direct Support Maintenance.
24-VOLT CONVERTER STAYS ON WITH SWITCH OFF
WARNING
Do not smoke or allow open flames or sparks nearby when performing battery maintenance. The mixture of oxygen and
the hydrogen gases released from batteries is flammable and can explode causing serious injury or death.
TA228614
2-91