TM 9-2320-269-20-1
ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
Q - QUARTERLY
S - SEMIANNUALLY
A - ANNUALLY
B - BIENNIALLY
H - HOURS
MI-MILES
INTERVAL
ITEM TO BE INSPECTED
ITEM
PROCEDURE: Check for and have repaired,
NO
Q
S
A
B
H
MI
filled, or adjusted as needed
3
BATTERY
WARNING
Do not smoke or allow open flames or sparks nearby when
performing battery maintenance. The mixture of oxygen and the
hydrogen gases released from batteries is flammable and can
explode causing serious injury or death.
Check terminal clamps and cables for tightness or corrosion.
Check water level. Fill if needed (TM 9-2320-269-10).
Do not overfill, and be sure filler caps are tight.
Check battery voltage. Test in accordance with
TM 9-6410-200-14.
Check operation of batteries (TM 9-2320-269-10).
TA228545