TM ll-5805-587-l5/3
TO 31W2-l-471-3
Timeout and Alarm Capability.
a . Purpose. T h e p u r p o s e o f t h i s t e s t i s t o v e r i f y t h a t t h e
translator, upon failure to complete translation within 1.7 seconds,
will time out and an alarm will be registered in the system.
b . Test Equipment and Materials. A hand test telephone, SC-
203585-000, is required for this test.
The following test
c. Test Connections and Conditions.
connections and conditions apply to this procedure.
(1) If the equipment must be kept in continuous operation,
perform t h i s t e s t d u r i n g p e r i o d s o f l i g h t t r a f f i c .
(2) The busy position for all BSY switches is with the slot
horizontal. The normal position is with the slot vertical.
(3) In the following test, it is assumed that translator A
is being tested. To test translator B, substitute A for B in the
control settings column for equipment under test.