TM 9-2320-269-20-2
TRANSMISSION COVER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
WARNING
Drycleaning solvent is both toxic and flammable. Avoid prolonged breathing of vapors and skin contact.
Do not use near open flame or excessive heat. Flashpoint of solvent is 1380F (590 C). Dispose of
solvent soaked rags properly.
4.
Transmission
Using putty knife, brush, rags, and dry-
cover (1)
cleaning solvent, remove old sealer from
transmission cover.
INSTALLATION
5.
Transmission
Apply silicone sealer around flange where
cover (1)
transmission cover (1) meets floor.
6.
Transmission
Three J-nuts (2)
Put on.
cover (1)
7.
Floor (3)
Transmission
Put in place.
cover (1)
8.
Transmission
10 screws (4)
Screw in, and tighten using 7/16-inch
floor (1) to
socket, handle, and extension.
TA229116
2-844