TM 11-5805-246-10
1-9. CAPABILITIES AND FEATURES.
MAJOR SYSTEM COMPONENTS
Converter case
Cover assembly
Spare fuse holder
Running spares
Mounting tracks
FEATURES
All weather operational
Portable
Can be used with or without mounting MT-791/U
1-10. DIFFERENCES BETWEEN MODELS.
Telegraph Terminal TH-5/TG can be used with Telephone Terminal TH-5A/TG. The TH-5A/TG model is a
modified TH-5/TG unit for use in the AN/TRC-80.
DIFFERENCE IN
TH-5A/TG
TH-5/TG
CHARACTERISTICS
115 volts, single phase
115 volts, single phase,
Line voltage
47 to 420 Hz
50 to 60 Hz
CPN 672-0124-00
50 to 60 Hz
47 to 420 Hz
7-pin miniature, short
7-pin miniature, long
Rectifier shield
-50 or -25 dbm
-50, -35, or -25 dbm
Receiving sensitivity
NOTE
Vacuum tubes V3, V4, V6, V13, V14 and V15 may be replaced with semiconductors
semiconductor 5961-00-645-2331. Locator diagrams will reference semiconductors which
may or may not be present. If a semiconductor is present, use a multimeter for tests.
1-4